一、概述
本裝(zhuang)置(zhi)(zhi)是適用于(yu)煤(mei)礦井下127V照明及信號負(fu)載的電(dian)(dian)(dian)源控制,并具(ju)有(you)短(duan)路保護,漏電(dian)(dian)(dian)保護及電(dian)(dian)(dian)纜絕緣危險指示綜合(he)性保護功能的隔(ge)爆(bao)(bao)型電(dian)(dian)(dian)氣設備。本裝(zhuang)置(zhi)(zhi)可以(yi)代(dai)替(ti)舊式15KVA、12.5KVA干式變壓器及手動隔(ge)爆(bao)(bao)開關(guan)的多體控制方式。電(dian)(dian)(dian)壓等(deng)級由(you)原660V/380V升(sheng)為(wei)(wei)1140V/660V。注(zhu)意:照明綜保內(nei)部(bu)變壓器容(rong)量較大(da),外殼(ke)容(rong)積較為(wei)(wei)緊湊,內(nei)部(bu)熱(re)量不易(yi)散發,綜保裝(zhuang)置(zhi)(zhi)必須放(fang)置(zhi)(zhi)在通(tong)風(feng)良好(hao)的位置(zhi)(zhi)使(shi)用。
二、產品特點
1、智能保(bao)護器,中(zhong)文液晶顯示、實時(shi)顯示電(dian)(dian)壓、電(dian)(dian)流、絕緣(yuan)電(dian)(dian)阻、工作狀態、故(gu)際類(lei)型、系統時(shi)間、系統參數;
2、短路(lu)保護(hu), 額(e)定電(dian)(dian)(dian)流(liu)可根據負載大小(xiao)調整,當系(xi)統電(dian)(dian)(dian)流(liu)大于該(gai)電(dian)(dian)(dian)流(liu)時,切斷(duan)供電(dian)(dian)(dian)電(dian)(dian)(dian)源(yuan)進行短路(lu)保護(hu)。
3、漏電(dian)閉鎖采用附加穩定直流電(dian)壓的方法檢測(ce)與保(bao)護。由單片(pian)機控制供電(dian)指(zhi)令,閉鎖值(zhi)不受電(dian)網電(dian)壓波動值(zhi)的影響。使(shi)裝置的可靠性進一(yi)步提(ti)高(gao)。
4、主(zhu)變壓(ya)(ya)器的鐵芯采(cai)用高導磁材料(liao),減小(xiao)了變壓(ya)(ya)器體積和(he)鐵損,提高了裝(zhuang)置的整體運(yun)行穩定性。
5、方形外殼,快開門結構,抽(chou)屜式本體,方便維修使(shi)用。
6、帶485通訊接口(kou),可實現在線監控功能。
7、智能(neng)控制可實(shi)現分時供電(dian)、無(wu)故(gu)障自(zi)送電(dian)、延時斷(duan)電(dian)等特殊使用功能(neng)。
三、主要技術參數
1、照明短路(lu)保護時間: < 100ms
2、信號短路(lu)保護時間: < 400ms
3、漏電(dian)保護動(dong)作時間(jian): < 250ms
4、漏電(dian)保護動作值: 2K2 士20%
5、漏電閉鎖(suo)電阻值: 4 K92 +20%
6、電纜絕緣危險指(zhi)示(shi)值: 12 K0 + 20%
7、工(gong)作(zuo)電壓允許波動(dong)范圍: Ue士 15% (V)